Skip to content

Screenshots show the Chinese interface. This part of the system is in Chinese only, so each button name is given in Chinese with an English translation.

Look up default parameters ​

Defaults of the most common detection rule parameters in one table, and what to change them to in which situations.

Applies to: Admin console and workstation stable release (2026-10-27)Updated 2026-10-28
ParameterDefaultNotes
Confidence0.5Can be lowered to 0.3 for small parts
Contact or connection · Overlap ratio0.05Edges touching
Contact or connection · Contact tolerance—Enter 5~10 px when the parts touch edge to edge without overlapping
Hand near object · Contact distance0.8 × palm
Grip object · Grip strength0.450.3 for pinching small parts
Action count · Dwell800 ms
Action count · Cumulative rotation270°
Action count · Reach distance1.5 × palm
Per-piece mode · Occlusion grace1500 ms
Per-piece mode · Minimum presence1000 ms
TimeoutNoneBlank = no timeout reported